Showing 60 of 330

Custom folder to keep HS2X files

Emile says that it would be better if we move the option to change the edited file save folder into Save Survey dialog instead of hiding it in the Settings? Not sure if this idea is really worth of adding but Emile insisted...
Ivan Izaak over 2 years ago in HYSWEEP 0 Planned

Tile Tiff export for high resolution tiffs

Would be good that we had an option for a high resolution tiff export so that users could get a single very high resolution image independent of screen resolution or zoom level within mbmax
Joshua Sampey over 3 years ago in HYSWEEP 1 Will not implement

Add a batch processing tool to MBMAX

Client at the conference found a way to trick auto processing to batch convert files to HS2X. This was great as a lower end computer could run prefilters and convert the data without sucking all of the system resources. This allowed the user to st...
Joshua Sampey almost 2 years ago in HYSWEEP 1 Planned

MBMAX64 - Cloud Window - set the center point to rotate the view (similar to CLOUD program?)

Suggested by Emile Foote (Shoreline Surveys, UK)
Ivan Izaak almost 3 years ago in HYSWEEP 0 Planned

HYSWEEP SURVEY Crashes with excessive Roll/Pitch value

If a big roll or pitch value comes (more than 45 degrees?), HYSWEEP SURVEY gives DOMAIN error and shuts down. Would be nice if it either gives a warning (but no crash)?
Ivan Izaak almost 3 years ago in HYSWEEP 0 Planned

Allow MB autoprocessing to be used for batch processing as well.

User suggested at the conference. They often have more data then they can open up in one session due to ram. They would like to use the auto processing in the office to convert the HSX to HS2X overnight
Joshua Sampey almost 2 years ago in HYSWEEP 0 Planned

Duplicate the hypothesis window from HYCUBE in MBMAX64

Due to HYCUBE would be nice to bring back the hypothesis window
Guest almost 3 years ago in HYSWEEP 0 Planned

MBMAX64-CUBE - adding a new TVU standard for Italy

COLMAR from Italy is asking to add a new TVU computation formula since Italian standard is more strict: In Italy we have a more restrictive Standard than the IHO Exclusive Order. In the TVU formula a2+(b×d)2 the a value is 0.10 m instead of 0.15 m...
Ivan Izaak almost 2 years ago in HYSWEEP 1 Planned

Add 'Return Mode' to LAS output from MBMAX64, if the LIDAR sends it to us.

The Velodyne LIDARs output the following information to HYSWEEP: The Velodyne VLP-16 ‘Point Return’ information consists of the following: A. Laser Return values (distances) B. Calibrated Reflectivity values (Intensities) C. Azimuth values D. Time...
Guest almost 2 years ago in HYSWEEP 1 Planned

Have the ability to remove high cell count pop up in editor.

When loading a large multibeam survey, this popup prevents editor from loading in the background.
Guest about 1 year ago in HYSWEEP 0