Skip to Main Content
Hypack User Ideas Portal
ADD A NEW IDEA

All ideas

Showing 330 of 330

Ability to right click and fill a matrix in the shell

Add an option when a matrix is clicked in the shell to fill it. Option should bring up a selection for type of data to use, Raw, Sorted etc and then user can select a file. Remove the need to open up mapper.
Joshua Sampey about 4 years ago in Hypack 1

"Add File and Copy" for BAG files

Currently you can only add a BAG file through "Add File", but not "Add File and Copy". Just a minor annoyance that I imagine would probably be an easy fix.
Calandria Decastro almost 3 years ago in Hypack 0

Support of Edgetech 2040DSS (combined SS and SBP)

After talks to Caryn, Joe and Boris I've decided to create an idea of developing a specific driver for the 2050 DSS by Edgetech as everyone says we can read sidescan (though it is a triple frequency so I am not sure about that) plus most definitel...
Ivan Izaak almost 3 years ago in Hypack 1

More options to print in SURVEY

Christian Shaw has asked for the following additions to SURVEY: -- The Print option in survey is a nice SMOutput.exe work around for marine construction albeit a bit clunky to configure and explain to customers. Its a "Print" function in HYPACK Ha...
Ivan Izaak almost 3 years ago in Hypack 0 Planned

Change A frame offsets in towfish.dll to be same as hardware (Forward, Starboard, Up)

Currently when a user opens up the towfish driver the offsets are labled as XYZ this is very confusing for users as we do not use XYZ notations in the standard offsets of hardware.
Joshua Sampey almost 3 years ago in Hypack 1

In survey add ability to delete target by right clicking on target in map window.

currently you can only disable targets with a right click and when you close survey and reopen they come back. Addition is to also relay the disabled status to the target selection to the shell so they don't reappear when survey is opened.
Joshua Sampey almost 3 years ago in Hypack 0

TIN Volume Report Resolution

Currently TIN Volumes Reports have 1 decimal resolution. A customer is asking to increase it to 2 decimals. His request came when he needed to enter 0.25 as Overdepth margin and the report shows 0.3 as Overdepth.
Ivan Izaak almost 3 years ago in Hypack 1 Planned

Remove the blank space below the device lists in Hardware

See screenshot. There's a good amount of blank space under the device lists in Hardware that could be used to show more devices at once. Extend the lists downward to utilise this space.
Guest almost 3 years ago in Hypack 0

ADCP - RDI Controller

Sending the Depth Range settings into RDI ADCP A customer did not change the Max Range of his RDI during survey and ended up with the gaps in the data when the bottom went too deep. He said it would be nice if he could send the Depth Range from HY...
Ivan Izaak almost 3 years ago in Hypack 0

Set limits for coverage in mosaicking

A function, where you can “cut” the inner and outer side of each channel when mosaicking it.It would greatly improve the quality of the Mosaick. See this video: https://www.youtube.com/watch?v=uQnN4Ov5Ndg at around 0:50 and 2:10 minute
Guest almost 3 years ago in Sidescan 0 Planned